Analog Current signal to RS485 or RS232 Converter/Analog data acquisition module.Slim-line plastic housing with integral 35mm DIN rail mounting , power supply(8-32VDC)

Products selection guide

WJ21 U(A)

Input signal(current/voltage) Communication Interface

U1:0-5V A1:0-1mA 485:RS-485 output interface

U2:0-10V A2:0-10mA 232:RS-232 output interface

U3:0-75mV A3:0-20mA

U4:0-2.5V A4:4-20mA

U5:0- ±5V A5:0-‚ ±1mA

U6:0-‚ ±10V A6:0-‚ ±10mA

U7:0-ƒ‚ ±100mV A7:0- ±20mA

U8:user-defined A8:user-defined

Products List Samples:

  • WJ21-A4-485 (4-20ma input signal, output is rs485 interface)

  • WJ21-A3-232 (0-20ma input signal,output is rs232 interface)

  • WJ21-A7-485(0-±20mA input,output is rs485 interface)

  • WJ21-A4-232 (4-20ma input signal, output is rs232 interface)

Other types,please check our datasheet.

Features:

  • Analog signal acquisition,isolated RS-485/232 output

  • 12-bit AD converter,testing accuracy>0.1%

  • Can be remotely reconfigured for modules accuracy

  • Three-port isolation(input/output/assistant power supply): 3000VDC

  • Power supply:8~32VDC

  • High reliability,easy programme,installation.

  • Can programme setting module address,baud rate

  • 0-5V/0-10V/0-12V voltage signal or 4-20mA/0-20mA current signal input

  • Support Modbus RTU

  • DIN35 Rail-mounted

  • Dimension:106.7x79.0x25.0mm

Application:

  • Signal testing/monitoring/cintrol

  • RS-232/485 industrial automation control system

  • Industial field signal isolation

  • Process Monitoring & Control

  • Test sensors signal

  • Laboratory Data Acquisition

  • Medical machine monitoring

  • 4-20mA/0-5V signal acquisition

General parameters: (typical @ +25 deg.C, Vs to 24VDC)

  • Input type: Input current / voltage input

  • Accuracy: 0.1%

  • Temperature drift:ƒ ‚‚ ± 30 ppm / (ƒ ‚‚ ± 50 ppm / maximum)

  • Input Resistance: 50 (4-20mA/0-20mA/0- ƒ ‚‚ ± 20mA current input)

  • 100(0-10mA/0- ± 10mA current input)

  • 1K(0-1mA/0-‚ ± 1mA current input)

  • 1M(voltage input)

  • Bandwidth: -3 dB 10 Hz

  • Conversion rate: 10 Sps

  • Common Mode Rejection (CMR): 120 dB (1kohm Source Imbalance @ 50/60 Hz)


  • Normal Mode Rejection (NMR): 60 dB (1kohmSource Imbalance @ 50/60 Hz)


  • Input Protection: over-voltage protection, over-current protection

  • Communication: RS-485 protocol or RS-232 standard characters protocols and MODBUS RTU communication protocol Baud Rate (1200,2400,4800,9600,19200,38400 bps) can be selected via software

Address (0 to 255) can be selected via software

  • Communication Response Time: 100 ms maximum

  • Power Supply: +8 ~ 32VDC wide range power supply, internal anti-reverse and over-voltage protection circuit

  • Power Loss: less than 1W

  • Operating Temperature: - 45 ~ +80 deg.C

  • Humidity: 10 ~ 90% (no condensation)

  • Storage Temperature: - 45 ~ +80 deg.C

  • Storage Humidity: 10 ~ 95% (no condensation)

  • Isolation Voltage: input / output: 3KVDC, 1 minute, leakage current:1mA

Which output signal and power supply are common ground.

  • Shock Voltage: 3KVAC, 1.2/50us (peak)

  • Dimensions: 106.7 mm x 79 mm x 25mm



SHENZHEN WAYJUN INDUSTRIAL AUTOMATION

* Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.

Listen to the Code(Audio Link)


Back to top
WAYJUN INDUSTRIAL AUTOMATION All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Ltd.(Terms of Use)
Developed and Managed by Infocom Network Ltd.